Home \ Research \ Scientific publications \


Determination of the reactivities and cross-reactivities of monoclonal antibodies against staphylococcal enterotoxin A by indirect ELISA and immunoblot including a semiautomated electrophoresis system

Investigation published in Letters in Applied Microbiology

May 1st, 1992

Eight murine monoclonal antibodies (Mabs) to staphylococcal enterotoxin A (SEA) were produced using standard hybridoma techniques. We studied reactivities and cross-reactivities by indirect ELISA and immunoblotting. Two of these Mabs (A5 and A7) reacted with five serovars (A-E) of SE in both systems. Only Mab A1 reacted specifically with the homologous toxin, while four Mabs reacted with SEA and SEE. Mabs A5 and A7 could be used to detect all five serovars of SEs in a single assay




Goyache J., Orden JA., Blanco JL., Domenech A., Hernandez J., Suarez G. and Gomez-Lucia E.




See this article
Determination of the reactivities and cross-reactivities of monoclonal antibodies against staphylococcal enterotoxin A by indirect ELISA and immunoblot including a semiautomated electrophoresis system

See it on NLM PubMed
Determination of the reactivities and cross-reactivities of monoclonal antibodies against staphylococcal enterotoxin A by indirect ELISA and immunoblot including a semiautomated electrophoresis system



Participants:

Universidad ComplutenseDepartamento de Sanidad Animal. Facultad de Veterinaria. Universidad Complutense (UCM).

Universidad ComplutenseServicio de Zoonosis Emergentes, de Baja Prevalencia y Agresivos Biológicos (NED). Centro de Vigilancia Sanitaria Veterinaria (VISAVET). Universidad Complutense (UCM).







Letters in Applied Microbiology
FACTOR YEAR Q
1.008 1997

NLMID: 8510094

PMID: 1368221

ISSN: 0266-8254



TITLE: Determination of the reactivities and cross-reactivities of monoclonal antibodies against staphylococcal enterotoxin A by indirect ELISA and immunoblot including a semiautomated electrophoresis system


JOURNAL: Lett Appl Microbiol


NUMERACIÓN: 14(5):217-20


AÑO: 1992


PUBLISHER: Published for the Society for Applied Bacteriology by Blackwell Scientific Publications


AUTHORS: Goyache J., Orden JA., Blanco JL., Domenech A., Hernandez J., Suarez G. and Gomez-Lucia E.


First
Joaquín Goyache Goñi
3rd
José Luis Blanco Cancelo
6th
Guillermo Suárez Fernández

DOI: https://doi.org/10.1111/j.1472-765X.1992.tb00689.x


CITE THIS PUBLICATION:

Goyache J., Orden JA., Blanco JL., Domenech A., Hernandez J., Suarez G. and Gomez-Lucia E. Determination of the reactivities and cross-reactivities of monoclonal antibodies against staphylococcal enterotoxin A by indirect ELISA and immunoblot including a semiautomated electrophoresis system. Letters in Applied Microbiology. 14(5):217-20. 1992. (A). ISSN: 0266-8254. DOI: 10.1111/j.1472-765X.1992.tb00689.x


UNITS: